ASCE 7 Calculator
|
| Uplift calculations are prepared based on ASCE 7 2010 Standards. Due to unknown variables associated with each roofing system and structure, Carlisle disclaims responsibility concerning the accuracy of these calculated results, the relevance of the results to the performance of the installed roofing system and the appropriate use of the program for any geographic location. A licensed engineer should verify the results. |
| Project Information | ||
| Job Name Project #1 | City Chambersburg | State/Prov, Country PA, US |
| User Name John Doe | Email jdoe@somesite.com | |
| Street Address 1144 Kennebec Drive | City Chambersburg | State/Prov, Country PA, US |
| Roof Dimensions (ft.) 3 x 3 | Building Height (ft.) 15 | Basic Wind Speed (mph) 90 |
| Exposure Type B | Internal Pressure Enclosed Buildings (0.18) | Building Category (IF) Category II |
| Membrane Type TPO | Deck Type Structural Concrete | Safety Factor 1 |
| Basic Uplift Pressure | |||||||
| Constant | Kz | Kzt | Kd | Vz2 | I | Qz | |
| 0.0256 | Velocity Pressure Coefficient |
Wind Speed Coefficient |
Directionality Factor |
Basic Wind Speed |
Allowable Strength Load |
Lbs./Sq. Ft. | |
| 0.00256 | 0.7 | 1 | 0.85 | 13225 | 0.6 | 12.1 | |
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mechanically Fastened | ||||
| Mechanically Fastened Membrane System Rated for 90 psf | ||||
|
||||
| Roof Zone | Maximum Space Between Rows of Securement | Number of Rows of Securements | ||
| Zone 1 (Field Area) | 9.5 ft. | |||
| Zone 2 (Perimeter Area) | 6 ft. | 1 | ||
| Zone 3 (Corner Area) | 6 ft. | 1 | ||
|